Amprobe AC50A AC Leakage Clamp Meter


Amprobe AC50A AC Leakage Clamp Meter
Amprobe AC50A AC Leakage Clamp Meter
Amprobe AC50A AC Leakage Clamp Meter
Amprobe AC50A AC Leakage Clamp Meter
Amprobe AC50A AC Leakage Clamp Meter

The Amprobe AC50A Clamp Multimeter with leakage current capability measures low AC current in the microamps. Great for applications requiring measurement of leakage and fault currents.


Amprobe AC50A AC Leakage Clamp Meter is rated 5.0 out of 5 by 2.
Rated 5 out of 5 by from Cost effective tool to measure leakage current; great for GFCIs The Amprobe AC50A is sensitive enough to measure the hot minus neutral current difference directly as well as the actual ground current. I was able to separate power leakage from ground loop current in a digital A-V studio environment, and trace the actual leaking devices that were causing a hard GFCI trip.
Date published: 2016-11-20
Rated 5 out of 5 by from Extremely useful and easy to use We have used this meter at multiple installations for field bus distributed I/O. The meter helped to determine leakage current and the source, which could cause communication problems and nuisance tripping. The meter is very useful in trouble shooting problems at new installations and existing issues, out in the field.
Date published: 2012-03-26
  • y_2017, m_12, d_9, h_19
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_73058, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_amprobe
  • AC current measurement to 60A
  • Leakage current measurement with resolution of 0.01mA
  • AC voltage to 400V
  • Resistance measurement and continuity beeper
  • Min/max control to see largest or smallest values in a series of measurements
  • Relative value measurement to determine differentials
  • Data hold to freeze measurement value on the display
  • Digital display with analog bargraph
  • Jaw opening 30 mm (1.2 in)
  • Auto-power off to save battery life
  • Minimum resolution 0.01mA
  • Included accessories Batteries, carrying case test leads, users manual
FEATURE AC50A
AC Voltage 400.0 V
AC Current 40.00 mA, 400.0 mA, 4.000 A, 40.00 A, 60.0 A
DC Current -
Resistance 400 O
Continuity
Accommodates conductors up to 1.2 (30 mm) in diameter

Specifications
Display: 3-3/4, LCD incl. functions and symbols
Bargraph: 40 segments
Range selection: manual
Auto-power off: approx. 30 min.
Overload display: the left digit is blinking
Measuring rate: 20 measurements/sec. (Bargraph), 2 measurements/sec. (LCD)
Clamp opening: ca. 30 mm (1.2)
Overvoltage category: CAT II, 600 V, CAT III, 300 V
Pollution degree: 2
Height above MSL: up to 2000 m, indoor operation
Battery display: at low battery
Power supply: Battery 2 x 1,5 V IEC LR6 (alkaline)
Current consumption: approx. 10 mA
Operation temperature: -10° C … 50° C (14° F... 122° F)
Storage temperature: -20° C … 60° C (-4° F... 140° F)
Humidity: < 75 % relative humidity



For complete specs please download the product datasheet under the “Resources" tab.
Model NameDescriptionBuy it
AC50A
  • AC current measurement to 60A
  • Leakage current measurement with resolution of 0.01mA
  • AC voltage to 400V
  • Resistance measurement and continuity beeper
           