amprobe
Australia [Change Country]
Home  |  Products  |  Clamp Meters  |  Industrial - Navigator, Power Quality, Large Jaw  |  
Contact usRefer this page

Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature


Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature

The ACD-40’s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.

THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100%


  • TRMS sensing measures Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
  • Total Harmonics Distortion THD, AC/DC Voltage up to 600V, AC Current up to 1000A, Resistance, Frequency, Temperature
  • Peak hold
  • Optional PC interface capability (RS-232 KIT2)
  • Audible continuity
  • Auto power off
  • Automatic polarity
  • Low battery indication
  • Data hold
  • Large, easy to read LCD display with backlight
  • Accommodates conductors up to 1.77” (45mm) in diameter
  • Carrying case, test leads, batteries (installed), thermocouple and manual included
  • Voltage overload protection for all functions up to 600V AC/DC
TRMS:    YES
AC Current    40.0 / 400.0 / 1000 A
AC Current Basic Accuracy:    +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz
DC Voltage:    600.0V
DC Voltage Basic Accuracy:    +/-(0.5% Rdg + 5 LSD)
AC Voltage:    600.0V
AC Voltage Basic Accuracy:    +/-(1.0% Rdg + 5 LSD) @ 50 / 60
Resistance:    999.9 Ohms
Resistance Basic Accuracy:    +/-(1.0% Rdg + 6 LSD)
Frequency:    5.00Hz to 500.0Hz
Frequency Basic Accuracy**:    +/-(0.5% Rdg +4 LSD)
THD-F *:    0.0% to 99.9%
THD-F * Basic Accuracy**:    1.5% of Reading + 6d @ Fund Frequency
Active Power (W):    0 to 600.0 kW
Active Power (W) Basic Accuracy**:    +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
Reactive Power (VAR):    0 to 600.0 kVAR
Reactive Power (VAR) Basic Accuracy**:    +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
Apparent Power (VA):    0 to 600.0 kVA
Apparent Power (VA) Basic Accuracy**:    +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th
Power Factor:    0.10 to 0.99
Power Factor Basic Accuracy**:    +/- 3 LSD @ Harmonics Fund to 21th
Temperature:    -58 F to 572 (-50 C to 300 C)
Temperature Basic Accuracy**:    +/-(2.0% Rdg + 6F) +/-(2.0 % Rdg + 3C)
Model NameDescription
ACD-41PQ
  • TRMS sensing measures Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
  • Total Harmonics Distortion THD, AC/DC Voltage up to 600V
  • AC Current up to 1000A, Resistance, Frequency, Temperature
Included Accessories:   Carrying case, test leads, batteries (installed), type-K thermocouple

Test Leads Probes and Clips
DL248DAmprobe DL248D

Other
ELS2AELS2A AC Current Clamp Accessory
Search
Find Resources
Find Products

Follow us  Google+       Home  |  About Us  |   Privacy Statement  |  Site Map  |   Contact Us© 1995 - 2017 Amprobe