Home  |  Products  |  Power Quality, Insulation and Ground Resistance Testers   |  Power Quality Analyzers   |  

Amprobe DM-III Multitest F 3000A Power Quality Recorder

Click here to watch video

Amprobe DM-III Multitest F 3000A Power Quality Recorder
Amprobe DM-III Multitest F 3000A Power Quality Recorder

Cut energy costs and improve operating efficiency with Amprobes full-featured DM-III Multitest F, a three-phase power quality recorder that provides the essential functions and capabilities required to operate accurately and effectively in today’s demanding electrical environments. The DM-III Multitest F measures and records a broad spectrum of power quality parameters with True-rms accuracy and is compatible with a wide range of current transducers.  This full-blown power quality recorder also measures ground resistance, tests insulation of wires, cables transformers and electrical motors.


Amprobe DM-III Multitest F 3000A Power Quality Recorder is rated 4.5 out of 5 by 4.
Rated 4 out of 5 by from Worth the investment This meter has a lot of useful features that can be used to monitor services, equipment, generators or individual circuits and grounding test capabilities. It can be used to record before and after any work done to document savings on power factor correction, energy efficient lighting, VFD's instead of cross the starters. Used in Harmonic recordings. Drawbacks are the limitations on single phase and delta recordings and the limited battery life. Otherwise it is worth the money.
Date published: 2015-05-28
Rated 5 out of 5 by from Great Tool to have. Replaced an older version DM II wiith this recorder. Much better reading quality and downloading is a breeze. Has more user friendly features and is 1/2 the size of the old unit. Has ground testing capabilities which the older unit did not have Definitely worth the investment !!!!!!!!!!!!!!!!!!
Date published: 2012-03-27
Rated 5 out of 5 by from Maintenance Electrician This product has great features, and will do multiple jobs.Very versital tool.
Date published: 2012-03-26
Rated 4 out of 5 by from This product has a lot of useful features This meter has a lot of useful features that can be used to monitor services, equipment, generators or individual circuits. It can be used to record before and after any work done to document savings on power factor correction, energy efficient lighting, VFD's instead of cross the starters. Used in Harmonic recordings. Only drawback is some limitations on single phase and delta recordings. Otherwise it is worth the money.
Date published: 2012-03-26
  • y_2017, m_6, d_19, h_18
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_US, sid_73223, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_amprobe
  • True-rms
  • Measures and records broad spectrum of power quality parameters: AC current, AC voltage to 600V including sags and surges, Harmonics (THD and individual up to 49th), active, reactive and apparent power & energy, peak demand, power factor, frequency measur
  • Compatible with wide range of current transducers
  • Comes as a complete kit: current transducers, voltage leads, ground probes & leads, PC software and download cable are included with this product.
  • Works with single and three phase systems (Y and Delta)
  • Detects and records voltage anomalies, sags and surges
  • Built in scope displays waveforms
  • Phase sequence indication
  • Records up to 64 parameters (single or three phase) simultaneously
  • Manual and programmable recording start
  • Password protection
  • Selectable fundamental frequency of 50 or 60 Hz
  • Special data compression system and user selectable rates allow recording from several hours to several years
  • Download capabilities, Windows compatible PC software
  • Displacement power factor for power factor correction determination
  • Line or battery powered
  • Megohmmeter functions: tests insulation of wires, cables, transformers and electrical motors
  • Selectable test voltages up to 1000V
  • Programmable timer to perform the dielectric absorption ratio test
  • Sensitive Ohmmeter for checking resistance of motor windings
  • Selectable polarization of ohmmeter for checking grounding continuity
  • Automatic voltmeter protects against misuse on hazardous energized systems
FEATURE DM-III MULTITEST DM-III MULTITEST F
AC Voltage 600 V
AC Currrent 1000 A 3000 A
Optional CT’s 1000 A, 3000 A 100 A
Harmonics THD, DC to 49th
Power W, VAR, VA
Energy Wh, WARh, VAh
Voltage anomalies Sag/surge
Power factor 0.00 +/- 1.00
Frequency 50 / 60 Hz
Phase sequence 1-2-3
Insulation tester 50 V, 100 V, 250 V, 500 V, 1000 V
Ground resistance Reisitance & resistivity

Specifications
Supplied current transducer: AM-FLEX33 3000A Flexible 7 internal diameter CT +/-(0.5% Rdg + 2 LSD
AC Current: DM-CT-100:0.5A to 100A / DM-CT-HTA:5 - 1000A /AM-FLEX33: selectable: 5 – 1000A or 15 - 3000A +/-(0.5% Rdg + 2 LSD)
AC Voltage including sags and surges: 0 - 600V +/-(0.5% Rdg + 2 LSD
Harmonics: THD, DC and individual up to 49th +/-(0.5% Rdg + 2 LSD)
Power: Working (W), reactive (VAR) and apparent (VA) +/-(1.0% Rdg + 2 LSD
Energy: Working (kWh), reactive (VARh) and apparent (VAh) +/-(1.0% Rdg + 2 LSD)
Peak demand: KW +/-(1.0% Rdg + 2 LSD)
Power factor: 0.00 – 1.00
Frequency measurement: 57 to 63.6 Hz at 60Hz fundamental 47 to 53 Hz at 50Hz fundamental +/-(1.0% Rdg + 2 LSD)
Phase sequence: 1 - 2 - 3
Co-generation: Computes incoming and outgoing energy
Selectable fundamental frequencies: 50/60 Hz
Available recording time: Several hours to several years depending on setup
Insulation resistance with 50V DC test voltage: 0.01-19.99, 49.9 +/- (2% reading + 2 digits) 49.9 - 99.9MO +/- (5% reading + 2 digits)
Insulation resistance with 100V DC test voltage: 0.01-19.99, 99.9 +/- (2% reading + 2 digits) 99.9 - 199.9MO +/- (5% reading + 2 digits)
Insulation resistance with 250V DC test voltage: 0.01-19.99, 199.9, 249 +/- (2% reading + 2 digits) 249 - 499MO +/- (5% reading + 2 digits)
Insulation resistance with 500V DC test voltage: 0.01-19.99, 199.9, 499 +/- (2% reading + 2 digits) 499 - 999 MO +/- (5% reading + 2 digits)
Insulation resistance with 1000V DC test voltage: 0.01-19.99, 199.9, 999 +/- (2% reading + 2 digits) 999 - 1999 MO +/- (5% reading + 2 digits)
Low resistance (without timer): 0.01-19.99, 99.9O+/- (2% reading + 2 digits)
Low resistance (with timer): 0.01-9.9O+/- (2% reading + 2 digits)
Ground resistance: 0-19.99, 199.9, 1999 O +/- (5% reading + 3 digits)
Ground resistivity: 0.6- 125.6 Om 0.125-1.256, 19.99, 199.9 kOm +/- (5% reading + 3 digits)



For complete specs please download the product datasheet under the “Resources" tab.
Model NameDescriptionBuy it
DM-III Multitest F
  • Power quality analyzer/ Data logger: True-rms
  • Works with single and three phase systems (Y and Delta)
  • Records up to 64 parameters (single or three phase) simultaneously
  • Megohmmeter functions: selectable test voltages up to 1000V
  • Ground resistance and resistivity functions: three measuring modes
  • Phase sequence indication
  • Compatible with wide range of current transducers , AM-FLEX33 supplied
Included Accessories:   External power supply, users manual, test leads, ground resistance test leads with 4 ground stakes,carrying case, PC software and USB cable, 3 current transducers (3000 amps)

Current TransducersBuy it
DM-CT-100Amprobe DM-CT-100 Current Transducer
DM-CT-HTAAmprobe DM-CT-HTA Clamp Attachment
           
Related Products

3 reviews
 
 Amprobe DM-II PLUS 1000A Power Quality Analyzer  »

3 reviews
 
 Amprobe DM-III Multitest 1000A Power Quality Recorder »