Home  |  Products  |  Clamp Meters  |  Industrial - Navigator, Power Quality, Large Jaw  |  

Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature


Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature

The Amprobe ACD-40 provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.

THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100%


Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature is rated 4.5 out of 5 by 2.
Rated 5 out of 5 by from Perfect for analyzing power quality. Simple, easy to use with many great features as the larger more expensive meters built right into this compact single phase recording device.
Date published: 2012-04-12
Rated 4 out of 5 by from Cost-effective power quality measurement A great tool! Entry-level power quality analysis at a fraction of the cost of other meters. Well constructed and easy to use. Wish the user manual were a little more helpful.
Date published: 2012-03-26
  • y_2017, m_12, d_12, h_19
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_73086, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_amprobe
  • True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
  • Total harmonics distortion (THD), AC/DC voltage up to 600V, AC current up to 1000A, resistance, frequency, temperature
  • Peak hold
  • Optional PC interface capability (RS-232 KIT2)
  • Audible continuity
  • Auto power off
  • Automatic polarity
  • Low battery indication
  • Data hold
  • Large, easy to read LCD display with backlight
  • Accommodates conductors up to 1.77 (45mm) in diameter
  • Carrying case, test leads, batteries (installed), thermocouple and manual included
  • Voltage overload protection for all functions up to 600V AC/DC
FEATURE ACD-41PQ ACD-45PQ
True-rms
AC Current 40.00 A, 400.0 A, 1000 A 40.00 A, 400.0 A, 600 A
AC/DC Voltage 600.0 V
Resistance 999.9 Ω
Continuity
Temperature -58 °F → 572 °F (-50 °C → 300 °C) -
Frequency 5.00 Hz → 500.0 Hz
Active power (W) 0 kW → 600.0 kW 0 kW → 360.0 kW
Reactive power (VAR) 0 kVAR → 600.0 kVAR 0 kVAR → 360.0 kVAR
Apparent power (VA) 0 kVA → 600.0 kVA 0 kVA → 360.0 kVA
Power Factor 0.10 → 0.99
Energy (KWHr)
Total Harmonic Distortion (THD%) 0.0 % → 99 % -
Accommodates Conductors up to 1.77" (45 mm) in diameter up to 1.02" (26 mm) in diameter

Specifications
TRMS: YES
AC Current: 40.0 / 400.0 / 1000 A
AC Current Basic Accuracy: +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz
DC Voltage: 600.0V
DC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD)
AC Voltage: 600.0V
AC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz
Resistance: 999.9O
Resistance Basic Accuracy: +/-(1.0% Rdg + 6 LSD)
Frequency: 5.00Hz to 500.0Hz
Frequency Basic Accuracy: +/-(0.5% Rdg +4 LSD)
THD-F *: 0.0% to 99.9%
THD-F * Basic Accuracy**: 1.5% of Reading + 6d @ Fund Frequency
Active Power (W): 0 to 600.0 kW
Active Power (W) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
Reactive Power (VAR): 0 to 600.0 kVAR
Reactive Power (VAR) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7
Apparent Power (VA): 0 to 600.0 kVA
Apparent Power (VA) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th
Power Factor: 0.10 to 0.99
Power Factor Basic Accuracy: +/- 3 LSD @ Harmonics Fund to 21th
Temperature: -58°F to 572° F (-50° C to 300° C)
Temperature Basic Accuracy: +/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C)



For complete specs please download the product datasheet under the “Resources" tab.
Model NameDescriptionBuy it
ACD-41PQ
  • TRMS sensing measures Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
  • Total Harmonics Distortion THD, AC/DC Voltage up to 600V
  • AC Current up to 1000A, Resistance, Frequency, Temperature
Included Accessories:   Carrying case, test leads, batteries (installed), type-K thermocouple

Test LeadsBuy it
DL248DAmprobe DL248D

OtherBuy it
ELS2AELS2A AC Current Clamp Accessory
           