Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature is rated
4.5 out of
5 by
2.
Rated 5 out of
5
by
Jerryrz from
Perfect for analyzing power quality.
Simple, easy to use with many great features as the larger more expensive meters built right into this compact single phase recording device.
Date published: 2012-04-12
Rated 4 out of
5
by
nscinc from
Cost-effective power quality measurement
A great tool! Entry-level power quality analysis at a fraction of the cost of other meters. Well constructed and easy to use. Wish the user manual were a little more helpful.
Date published: 2012-03-26
|
- True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
- Total harmonics distortion (THD), AC/DC voltage up to 600V, AC current up to 1000A, resistance, frequency, temperature
- Peak hold
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Auto power off
- Automatic polarity
- Low battery indication
- Data hold
- Large, easy to read LCD display with backlight
- Accommodates conductors up to 1.77 (45mm) in diameter
- Carrying case, test leads, batteries (installed), thermocouple and manual included
- Voltage overload protection for all functions up to 600V AC/DC
|
| True-rms |
• |
| AC Current |
40.00 A, 400.0 A, 1000 A |
40.00 A, 400.0 A, 600 A |
| AC/DC Voltage |
600.0 V |
| Resistance |
999.9 Ω |
| Continuity |
• |
| Temperature |
-58 °F → 572 °F (-50 °C → 300 °C) |
- |
| Frequency |
5.00 Hz → 500.0 Hz |
| Active power |
(W) 0 kW → 600.0 kW |
0 kW → 360.0 kW |
| Reactive power (VAR) |
0 kVAR → 600.0 kVAR |
0 kVAR → 360.0 kVAR |
| Apparent power (VA) |
0 kVA → 600.0 kVA |
0 kVA → 360.0 kVA |
| Power Factor |
0.10 → 0.99 |
| Energy (KWHr) |
• |
• |
| Total Harmonic Distortion (THD%) |
0.0 % → 99 % |
- |
| Accommodates Conductors |
up to 1.77" (45 mm) in diameter |
up to 1.02" (26 mm) in diameter |
| Specifications |
| TRMS: |
YES |
| AC Current: |
40.0 / 400.0 / 1000 A |
| AC Current Basic Accuracy: |
+/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
| DC Voltage: |
600.0V |
| DC Voltage Basic Accuracy: |
+/-(0.5% Rdg + 5 LSD) |
| AC Voltage: |
600.0V |
| AC Voltage Basic Accuracy: |
+/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
| Resistance: |
999.9O |
| Resistance Basic Accuracy: |
+/-(1.0% Rdg + 6 LSD) |
| Frequency: |
5.00Hz to 500.0Hz |
| Frequency Basic Accuracy: |
+/-(0.5% Rdg +4 LSD) |
| THD-F *: |
0.0% to 99.9% |
| THD-F * Basic Accuracy**: |
1.5% of Reading + 6d @ Fund Frequency |
| Active Power (W): |
0 to 600.0 kW |
| Active Power (W) Basic Accuracy: |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
| Reactive Power (VAR): |
0 to 600.0 kVAR |
| Reactive Power (VAR) Basic Accuracy: |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
| Apparent Power (VA): |
0 to 600.0 kVA |
| Apparent Power (VA) Basic Accuracy: |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
| Power Factor: |
0.10 to 0.99 |
| Power Factor Basic Accuracy: |
+/- 3 LSD @ Harmonics Fund to 21th |
| Temperature: |
-58°F to 572° F (-50° C to 300° C) |
| Temperature Basic Accuracy: |
+/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C) |
For complete specs please download the product datasheet under the “Resources" tab.
|
| Model Name | Description | Price List | Buy it | | ACD-41PQ | - TRMS sensing measures Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
- Total Harmonics Distortion THD, AC/DC Voltage up to 600V
- AC Current up to 1000A, Resistance, Frequency, Temperature
Included Accessories: Carrying case, test leads, batteries (installed), type-K thermocouple |  |
| Test Leads | Buy it | | DL248D | Amprobe DL248D |  |
| Other | Buy it | | ELS2A | ELS2A AC Current Clamp Accessory |  |
|
|
|
|
|
|
|
|